Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
Home Print this page Email this page Small font size Default font size Increase font size Users Online: 237
ORIGINAL ARTICLE
Year : 2013  |  Volume : 36  |  Issue : 3  |  Page : 138-142

Dosimetric analysis of intensity modulated radiotherapy plans having one or more pairs of parallel opposed beams among the set of beams in some special cases


Department of Physics, Mewar University, Chittorgarh, Rajasthan, India

Correspondence Address:
Om Prakash Gurjar
(Ph.D. Scholar - Mewar University), Asstt. Professor (Med. Phys.) and RSO (III), ROS SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Sciences, Indore - 453 111
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-0464.137480

Rights and Permissions

The purpose of this study was to analyze the dosimetric parameters of intensity modulated radiotherapy (IMRT) plans with a set of beams having one or more pairs of parallel opposed beams for the pelvis, head-and-neck (H and N) and brain cases having large secondary nodes. We selected three pelvis (carcinoma of prostate with pelvic bony mets), three  H and N (two cases of carcinoma of the parotid with large secondary nodes and one case of carcinoma of the base of the tongue with large secondary nodes), and three brain (glioblastoma multiform) IMRT patients. IMRT plans were done with a set of 6-9 beams having one or more pairs of parallel opposed beams. Each plan was done using 6 MV photon energy. Each plan was analyzed on the basis of planning target volume (PTV) coverage with 93%, 95%, 100%, 107%, and 110% of the prescribed dose (PD), organs at risk (OAR) doses, homogeneity index (HI), conformity index (CI), and normal tissue integral dose (NTID). The doses to OARs were well within tolerance limits and the PTV coverage for 93%, 95%, and 100% of PD was obtained very well (followed the radiation therapy oncology group criteria "95% and 99% volume of PTV should receive 95% and 93% of the PD, respectively"), and values of HI, CI, and NTID were also satisfactory. In summary, very good OAR sparing and PTV coverage were observed in all plans. Hence, it can be concluded that use of one or more pairs of parallel opposed beams in IMRT plans in some special cases as selected for this study offers the benefit in terms of critical target volume irradiation, while maintaining the OAR within tolerable limits.


[FULL TEXT] [PDF]*
Print this article     Email this article
Next article
Previous article
Table of Contents
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Citation Manager
Access Statistics
Reader Comments
Email Alert *
Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2404    
    Printed24    
    Emailed3    
    PDF Downloaded241    
    Comments [Add]    
    Cited by others 3    

Recommend this journal