Dose mapping of FIPLY food irradiator


1 Radiation Safety Systems Division, BARC, Mumbai, India
2 Food Technology Division, BARC, Mumbai, India

Date of Web Publication1-Dec-2011

Correspondence Address:
S Murali
Radiation Safety Systems Division, BARC, Mumbai
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions
  Abstract 

The 60 Co source is used in the FIPLY irradiator. The source is stored under water and the water pool acts as the shield and is useful for the removal of the decay heat. The radiation field measurement on the water pool area was desired to be carried out for different depths of water and during the source held in the exposed state, gamma dose mapping in the irradiator room with distance from the source rack. The paper describes the radiation field prevailing at various depths of water pool with source under water and gamma dose with distance in the irradiator room during the sources held in the exposed state.

Keywords: Food irradiator, gamma dose mapping, 60 Co source


How to cite this article:
Ojha S, Bairwa SM, Suman S K, Ram A K, Yadav R K, Murali S. Dose mapping of FIPLY food irradiator. Radiat Prot Environ 2010;33:192-4

How to cite this URL:
Ojha S, Bairwa SM, Suman S K, Ram A K, Yadav R K, Murali S. Dose mapping of FIPLY food irradiator. Radiat Prot Environ [serial online] 2010 [cited 2021 Aug 3];33:192-4. Available from: https://www.rpe.org.in/text.asp?2010/33/4/192/90464


  1. Introduction Top


Food materials are gamma irradiated for select doses for disinfestations and increasing the shelf life of the products. The FIPLY irradiator is used for the purpose needed the gamma dose mapping for the two sources-held under water and in exposed conditions radiation field vis-à-vis the distance in the irradiator room. The experiments were conducted on different occasions and for different source conditions. The gamma dose mapping results are useful for planning the time period of irradiation for food materials, since presently films/dosimeters are used for the verification of irradiation dose.

1.1 Food irradiator

Irradiation is carried out inside an irradiator chamber shielded by 1.5-1.8m thick concrete walls. Material either prepacked or in-bulk placed in suitable containers sent into the irradiation chamber with help of an automatic conveyor. The conveyor goes through a concrete wall labyrinth, which prevents radiation from reaching the work area and operator room. When the facility is not in use the radiation source is stored under 6m deep water. The water shield does not allow radiation to escape into the irradiation chamber, thus permitting free access to personnel to carry out plant maintenance. For treating material, the source is brought to the irradiation position above the water level after activation of all safety devices. The goods in aluminium carriers or tote boxes are mechanically positioned around the source rack and are turned round their own axis, so that contents are irradiated on both the sides. [Figure 1] indicates the points at which the radiation fields were measured.
Figure 1: FIPLY Irradiator layout

Click here to view


1.2 Instrument used

Teletector (Automess), Teletector with 20 m long cable probe (Automess), PLA radiation monitor (hand held unit).


  2. Experimental Top


The source of 60 Co is used irradiation purposes with two different strengths viz.

a) 11. kCi b) 45. 3 kCi, and (a) + (b) 56. 7 kCi

Gamma dose mapping of the area was carried out with the sources in the exposed condition.

  1. Source (a) 11. kCi held in exposed condition, the other source (b) 45. 3 kCi under water.
  2. Sources (a) + (b) 56.7 kCi held in exposed condition.



  3. Results Top


The results of radiation field measurements carried out at different depths for source under water are tabulated in [Table 1]. It indicates that the radiation field at a depth of 3m or more from the surface of water could be useful for planned exposure to deliver irradiation dose to the sample lowered accordingly.
Table 1: Dose rate inside Water Pool Food irradiator (Source under water)

Click here to view


The results of radiation field measurements carried out at different distances from the sources (a) and (a) + (b) in the irradiator room for source in the exposed state are tabulated in [Table 2].
Table 2: Radiation field in the irradiator room

Click here to view



  4. Conclusion Top


The gamma dose mapping results are useful for planning the time period of irradiation for food materials, since presently films/dosimeters are used for the verification of irradiation dose. The gamma dose mapping of the irradiator area is useful to estimate the irradiation dose to the system materials and corresponding radiation degradation.


  5. References Top


Technical Specification - FIPLY irradiator (1995).


    Figures

  [Figure 1]
 
 
    Tables

  [Table 1], [Table 2]



 

Top
   
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
1. Introduction
2. Experimental
3. Results
4. Conclusion
5. References